Atmospheric Science / Thermodynamics

Heating balancing adiabatic cooling
In a hydrostatic atmosphere a rising dry parcel cools at the dry adiabatic rate, i.e. it loses energy at a rate g·w per unit mass (cp·dT/dt = −g·w). To keep the temperature constant, the heating rate Q = g·w, so w = Q/g = 0.05/9.8 ≈ 5.1 × 10⁻³ m/s ≈ 0.5 cm/s.
1. 0.5 cm/s - correct. 2. 5.0 cm/s - incorrect. 3. 0.05 cm/s - incorrect. 4. 50 cm/s - incorrect.