2018_june Booklet A Part C Q97 📚 Electrical methods

CSIR NET June 2018 Q97: Electrical methods

Medium
Question 97

Select your answer:

Combined VES curve types.
Consecutive 3-layer curve types share layers: the second type must start with the resistivity trend in which the first ended. KA (ρ1 < ρ2 > ρ3 then ρ2 > ρ3 < ρ4 would be KH) is not a valid four-layer combination (option 4).
—

Similar Questions from Other Years (12)

error: Content is protected !!
Chat on WhatsApp